Domus - Tiles, Stone, Wood and Engineered Flooring

Image search Find the closest match

Or select from one of ours

Product Information

Oak top layer. Välinge Compositek core. Natural wood backing Select (WDVLS 201 204, 206 & 208) Nature (WDVLN 201 213, 301 & 302) N/A Woodura® 4-way micro-bevel FSCMix Internal use only. Suitable with underfloor heating 2G (long edges). 5G® Drywaterproof technology (short edges) Recommended for floated or bonded installation Limed ( WDVLS 201, WDVLN 201 , WDVLN 211213) Smoked ( WDVLN 301 & 302 ) Tinted (all other colours) Material: Grades: Brushing: Technology: Edge Detail: Certification: Application: Installation: Treatments: Specification 1 206 x 2200 Size (mm) All colours Colour Availability Thickness (Lamella) 11.3 (0.6) Finish UV Cured Acrylic Swatch colours may vary from original. Samples should be requested. 1
Ash top layer (WDVLS 401, 402 & 404). Walnut top layer (WDVLN 503 & 506). Välinge Compositek core. Natural wood backing. Select (WDVLS 401, 402 & 404) Nature (WDVLN 503 & 506) N/A Woodura® 4-way micro-bevel FSCMix Internal use only. Suitable with underfloor heating 2G (long edges). 5G® Drywaterproof technology (short edges) Recommended for floated or bonded installation Limed (WDVLS 401) Tinted (all other colours) Materials: Grades: Brushing: Technology: Edge Detail: Certification: Application: Installation: Treatments: Specification 1 206 x 2200 Size (mm) All colours Colour Availability Thickness (Lamella) 11.3 (0.6) Finish UV Cured Acrylic Swatch colours may vary from original. Samples should be requested. 1
CLASSIFICATION & SAFETY PROPERTIES All test results are based upon current test data provided by the manufacturer and are provided in good faith. Domus Group Limited cannot be held responsible for any variation in the test data due to changes in manufacture or material characteristics. Errors & omissions excepted. Please refer to Domus Group Limited Terms & Conditions of Sale, 10 July 2023 4:31 pm Fire resistance Thermal conductivity Thermal resistance Formaldehyde emission Brinell hardness Impact resistance Thickness swelling Wear resistance Slip resistance (USRV) Slip resistance (pendulum) Coefficient of friction Level of use (domestic) Level of use (commercial) Technical Characteristics Industry Standard EN 13501 EN 12664 EN 12667 EN 717-1 EN 1534 EN 14354 EN 14354 EN 14354 CEN/TS 15676 BS EN 16165 EN ISO 10874 EN ISO 10874 Performance Bfl-S1 (hardly fllammable) 0.16W/(m*K) 0.07(m 2 xK)/W E1 10HB (average value) EC3 <8% >6000 cycles 40 Test results upon request Class 23 Heavy Residential Class 33 Heavy Commercial Compatible with underoor heating systems subject to K21 installation advice available on request.
Oak top layer. Välinge Compositek core. Natural wood backing Select (WDVLS 201 204, 206 & 208) Nature (WDVLN 201 213, 301 & 302) N/A Woodura® 4-way micro-bevel FSCMix Internal use only. Suitable with underfloor heating 2G (long edges). 5G® Drywaterproof technology (short edges) Recommended for floated or bonded installation Limed ( WDVLS 201, WDVLN 201 , WDVLN 211213) Smoked ( WDVLN 301 & 302 ) Tinted (all other colours) Material: Grades: Brushing: Technology: Edge Detail: Certification: Application: Installation: Treatments: Specification 1 206 x 2200 Size (mm) All colours Colour Availability Thickness (Lamella) 11.3 (0.6) Finish UV Cured Acrylic Swatch colours may vary from original. Samples should be requested. 1
Ash top layer (WDVLS 401, 402 & 404). Walnut top layer (WDVLN 503 & 506). Välinge Compositek core. Natural wood backing. Select (WDVLS 401, 402 & 404) Nature (WDVLN 503 & 506) N/A Woodura® 4-way micro-bevel FSCMix Internal use only. Suitable with underfloor heating 2G (long edges). 5G® Drywaterproof technology (short edges) Recommended for floated or bonded installation Limed (WDVLS 401) Tinted (all other colours) Materials: Grades: Brushing: Technology: Edge Detail: Certification: Application: Installation: Treatments: Specification 1 206 x 2200 Size (mm) All colours Colour Availability Thickness (Lamella) 11.3 (0.6) Finish UV Cured Acrylic Swatch colours may vary from original. Samples should be requested. 1
CLASSIFICATION & SAFETY PROPERTIES All test results are based upon current test data provided by the manufacturer and are provided in good faith. Domus Group Limited cannot be held responsible for any variation in the test data due to changes in manufacture or material characteristics. Errors & omissions excepted. Please refer to Domus Group Limited Terms & Conditions of Sale, 10 July 2023 4:31 pm Fire resistance Thermal conductivity Thermal resistance Formaldehyde emission Brinell hardness Impact resistance Thickness swelling Wear resistance Slip resistance (USRV) Slip resistance (pendulum) Coefficient of friction Level of use (domestic) Level of use (commercial) Technical Characteristics Industry Standard EN 13501 EN 12664 EN 12667 EN 717-1 EN 1534 EN 14354 EN 14354 EN 14354 CEN/TS 15676 BS EN 16165 EN ISO 10874 EN ISO 10874 Performance Bfl-S1 (hardly fllammable) 0.16W/(m*K) 0.07(m 2 xK)/W E1 10HB (average value) EC3 <8% >6000 cycles 40 Test results upon request Class 23 Heavy Residential Class 33 Heavy Commercial Compatible with underoor heating systems subject to K21 installation advice available on request.

You may also like…